Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
data is from experimental reports
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
The particle size distribution of test item Methyl nicotinate (CAS No. 93-60-7 ) was determined by granulometric analysis with rotap sieve shaker.
GLP compliance:
not specified
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
counted distribution
Specific details on test material used for the study:
- Name of test material (as cited in study report): Methyl nicotinate
- Molecular formula: C7H7NO2
- Molecular weight: 137.137 g/mol
- Smiles notation: c1(C(OC)=O)cccnc1
- InChI: 1S/C7H7NO2/c1-10-7(9)6-3-2-4-8-5-6/h2-5H,1H3
- Substance type: Organic
- Physical state: Solid
Key result
Percentile:
D50
Remarks on result:
other: Mass median diameter
No.:
#1
Size:
150 µm
Distribution:
100 %
Remarks on result:
other: no other details mentioned

O BSERVATION TABLE

Amount of test item weighed (g)=10.896

Method run time(minute)=5 min

 

 

Sieve sizes(in

microns)

Weight of petridishes + test

item(g)

 

Test item quantity

retained after sieving (g)

 

Percentage(%)of

test item*

 
 150  57.161 10.563   100.00

 

Percentage of test item =   Test item retained on each sieve after sieving X 100

                                                   Original test item taken

 

Conclusions:
The particle size distribution of test item Methyl nicotinate (CAS No. 93-60-7 ) was determined by granulometric analysis with rotap sieve shaker. The particle size of methyl nicotinate was determined to be 150micron .
Executive summary:

The particle size distribution of test item Methyl nicotinate (CAS No. 93-60-7 ) was determined by granulometric analysis with rotap sieve shaker. The particle size of methyl nicotinate was determined to be 150micron .

Description of key information

The particle size distribution of test item Methyl nicotinate (CAS No. 93-60-7 ) was determined by granulometric analysis with rotap sieve shaker. The particle size of methyl nicotinate was determined to be 150micron .

Additional information

The particle size distribution of test item Methyl nicotinate (CAS No. 93-60-7 ) was determined by granulometric analysis with rotap sieve shaker. The particle size of methyl nicotinate was determined to be 150micron .