Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
calculation (if not (Q)SAR)
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Deviations:
no
GLP compliance:
yes (incl. certificate)
Specific details on test material used for the study:
Identification: 2-Propenoic acid, 2-[[(octadecylamino)carbonyl]oxy]ethyl ester
Appearance/Physical state: White solid
Purity: >98%
Storage conditions: Room temperature in the dark
Key result
Sample tested:
other: Structure review
Remarks:
Structure revie
Parameter:
other: The structure of the test item was assessed for chemical groups that imply oxidising properties.
Remarks on result:
other: negative
Remarks:
There are no structural alerts within the chemical structure of the test item.

There are no structural alerts within the chemical structure of the test item.

Interpretation of results:
GHS criteria not met
Conclusions:
Based on the chemical structure of the test item the result for the oxidizing properties has been predicted negative.

Description of key information

In an EU A.174 Method study, under GLP conditions, based on the chemical structure of 2-Propenoic acid, 2-[[(octadecylamino)carbonyl]oxy]ethyl ester is predicted to be non oxidising (Envigo, 2016b).

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification