Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted following ASTM D93 -Procedure A
Qualifier:
according to
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
Procedure A
Deviations:
no
GLP compliance:
no
Remarks:
conducted under good manufacturing practices (GMP)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks on result:
no flash point up to 100°C
Remarks:
A small distinct flash was noted at at 105°C. Continued to heat up to 110°C the flame was extinguished with no flash
Conclusions:
Not able to determined flash point using ASTM D93 Procedure A. No flash point up to 100°C. A small distinct flash was noted at 105°C, however after continued to heat up to 110°C the flame was extinguished with no flash.

Description of key information

Not able to determined flash point using ASTM D93 Procedure A. No flash point up to 100°C. A small distinct flash was noted at 105°C, however after continued to heat up to 110°C the flame was extinguished with no flash.

Key value for chemical safety assessment

Additional information