Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study under GLP conditions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Details on test material:
Batch PC5
Purity: 97.9 %

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0 Pa
Remarks on result:
other: The caluclated vapour pressure value is extrapolated.
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: The caluclated vapour pressure value is extrapolated.
Temp.:
50 °C
Vapour pressure:
0 Pa
Remarks on result:
other: The caluclated vapour pressure value is extrapolated.