Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1995

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: VDI 2263 Part 1
Principles of method if other than guideline:
Testing for Impact Sensitivity
The test is performed with the falling hammer (impact energy 40 J). If at least in one out of ten times, without the sensitizing aluminum-wrapping, a blast is registered, the substance is shock sensitive. otherwise is " not sensitive to impact. "With impact-sensitive materials, an additional investigation is required under the explosives Act.
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
Disperse Blue 79:1
IUPAC Name:
Disperse Blue 79:1
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
not measured/tested
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
not measured/tested
Parameter:
other: Explosive under influence of flame
Remarks:
migrated information
Remarks on result:
not measured/tested
Parameter:
other: Explosive (not specified)
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Remarks:
not sensitive to impact (ca. 40 J)

Applicant's summary and conclusion

Interpretation of results:
non explosive
Remarks:
Migrated information
Conclusions:
The substance was tested for impact sensitivity following VDI 2263 Part 1. Under the experimental conditions the substance is not considered explosive.
Executive summary:

The substance was tested for impact sensitivity following VDI 2263 Part 1. Impact sensitivy was tested by means of a falling hammer ( 40J). Under the experimental conditions the substance is not considered explosive.