Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental Starting Date: 16 March 2016; Experimental Completion: 16 March 2016; Study Completion Date: 22 March 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
None
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
mass based distribution
Specific details on test material used for the study:
Identification: FAT 20013/D TE Lot. 1502011 (China)
Appearance: Black powder
Mass median aerodynamic diameter:
23.578 µm
Key result
Percentile:
D10
Mean:
5.705 µm
Remarks on result:
other: L10 = 5.705 μm
Key result
Percentile:
D50
Mean:
23.578 µm
Remarks on result:
other: L50: 23.578 μm
Key result
Percentile:
other: L100
Mean:
73.496 µm
Remarks on result:
other: Standard deviation not available
Conclusions:
The median particle size (L50) of FAT 20013 was found to be 23.578 µm.
Executive summary:

The particle size of FAT 20013 was determined in a study conducted according to the guidelines CIPAC MT 187 and ISO 13320 -1. Lased diffraction method was used for this purpose. Based on the findings of the study, L10, L50 and L90 for the test substance were determined to be 5.705, 23.578 and 79.496 µm, respectively. Hence, the median particle size (L50) of FAT 20013 was determined to be 23.578 µm.

Description of key information

The particle size of FAT 20013 was determined in a study conducted according to the guidelines CIPAC MT 187 and ISO 13320 -1. Lased diffraction method was used for this purpose. Based on the findings of the study, L10, L50 and L90 for the test substance were determined to be 5.705, 23.578 and 79.496 µm, respectively. Hence, the median particle size (L50) of FAT 20013 was determined to be 23.578 µm.

Additional information