Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 August 2008 - 09 October 2008
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test performed in accordance with EC A.10 guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Test material form:
solid: crystalline
Details on test material:
- Substance type: white powder
- Physical state: solid
- Analytical purity: 99.80%
- Expiration date of the lot/batch: 31 Jan 2009
- Storage condition of test material: At room temperature in the dark

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Applicant's summary and conclusion

Conclusions:
The test substance was not considered highly flammable.
Executive summary:

The preliminary screening test was performed for the determination of the flammability of the test substance. No propagate combustion of the test substance along 200mm length of pile within 4 minutes was observed. Based on this, the test substance was not considered highly flammable.