Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. QA statement)
Type of method:
other: Grain Watson estimation

Test material

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
<= 0.059 Pa

Applicant's summary and conclusion

Conclusions:
The test item has a vapour pressure of < 0.059 Pa at 20°C.