Registration Dossier

Administrative data

Endpoint:
flammability
Remarks:
Pyrophoric liquids/solids (migrated from section 'Flammability')
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Compliance

Data source

Reference
Reference Type:
other: Body Responsible for the test
Title:
Unnamed

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 84/449/EWG, A.10
Principles of method if other than guideline:
Method A9/A2
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

The substance does not burn easily and is not considered flammalbe under the criteria of method A10

A.12 Test not conducted since, due to the chemical structure of the substance, the possibility of the substance forming flammable gases on contact with water or moist air can be excluded.

A.13 Test not conducted because the substance can be handled in air without self-ignition

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Material is not classified in any flammable categories.