Registration Dossier

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because there are no chemical groups present in the molecule which are associated with oxidising properties and hence, the classification procedure does not need to be applied
Interpretation of results:
GHS criteria not met

Description of key information

not oxidising  (EU A.17)

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

The test material does not contain fluorine nor chlorine. The contained oxygen is chemically bounded only to carbon or hydrogen.

Justification for classification or non-classification