Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 23, 2007 - July 26, 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: study conform with Directive EEC 92/69, A.1, OECD Guideline No. 102

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary method

Test material

Constituent 1
Details on test material:
Identity: AES
Batch: LSF7
Purity: 80.3%
Appearance: Solid
Expiration date: February 15, 2008
Storage: In the refrigerator at about 4 °C

Results and discussion

Melting / freezing point
Melting / freezing pt.:
ca. 133 °C
Atm. press.:
99.2 kPa
Decomposition:
yes
Decomp. temp.:
ca. 150 °C

Applicant's summary and conclusion

Conclusions:
AES melted at about 133°C followed by a change of crystalline structure.

Categories Display