Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February - April 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 169 & 170
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Test Substance Name: LZ 514
- Source: Lonza Ltd, Visp/Switzerland
- Lot/batch No.of test material: 5011
- Expiration date of the lot/batch: 2nd December 2017
- Manufacture date: 3rd December 2015

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage conditions: Controlled room temperature (15-25 ºC, below 70 RH%), protected from light and humidity.
- Stability under test conditions: stable
- Safety precautions: Routine safety precautions (lab coat, gloves, safety glasses, face mask) for unknown materials were applied to assure personnel health and safety.
Remarks on result:
not determinable because of methodological limitations
Key result
Percentile:
D10
Mean:
> 4 µm
St. dev.:
0
Key result
Percentile:
D90
Mean:
> 125 µm
St. dev.:
0
No.:
#1
Size:
63 µm
Distribution:
98.1 %
Remarks on result:
other: sum of residues Rx %
No.:
#2
Size:
125 µm
Distribution:
93.4 %
Remarks on result:
other: sum of residues Rx %
No.:
#3
Size:
250 µm
Distribution:
86 %
Remarks on result:
other: sum of residues Rx %
No.:
#4
Size:
500 µm
Distribution:
69.8 %
Remarks on result:
other: sum of residues Rx %
No.:
#5
Size:
1 000 µm
Distribution:
46.4 %
Remarks on result:
other: sum of residues Rx %
No.:
#6
Size:
2 000 µm
Distribution:
29.8 %
Remarks on result:
other: sum of residues Rx %
No.:
#7
Size:
4 000 µm
Distribution:
0.1 %
Remarks on result:
other: sum of residues Rx %
Conclusions:
The particle size distribution of the test item was found to be [125 μm; 4000 μm]. Less than 10% of the test item is larger than 4 mm and more than 90% is larger than 125 μm.
Executive summary:

The study was performed according to CIPAC methods MT 169 & 170, using the sieving method.

The particle size distribution of the test item was found to be [125 μm; 4000 μm]. Less than 10% of the test item is larger than 4 mm and more than 90% is larger than 125 μm.

Description of key information

The study was performed according to CIPAC methods MT 169 & 170, using the sieving method.

The particle size distribution of the test item was found to be [125 μm; 4000 μm]. Less than 10% of the test item is larger than 4 mm and more than 90% is larger than 125 μm.

Additional information

Source: GLP-report