Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 28 October 2015 and 23 December 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study is considered to be a reliability 1 as it has been conducted according to EU Method A9 using a closed cup flash point method and in compliance with GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Key result
Flash point:
99.21 °C
Atm. press.:
100.4 kPa

Results of the flash point determination are shown in the following table.

Temperature (ºC)

Observations

20.0

No flash.

25.0

No flash.

30.0

No flash.

35.0

No flash.

40.0

No flash.

45.0

No flash.

50.0

No flash.

55.0

No flash.

60.0

No flash.

65.0

No flash.

70.0

No flash.

70.0 (fresh sample)

No flash.

75.0

No flash.

80.0

No flash.

85.0

No flash.

90.0

No flash.

95.0

No flash.

100.0

A blue flash spread across the sample cup.

100.0 (fresh sample)

A blue flash spread across the sample cup.

95.0 (fresh sample)

No flash.

96.0 (fresh sample)

No flash.

97.0 (fresh sample)

No flash.

98.0 (fresh sample)

No flash.

99.0 (fresh sample)

A blue flash spread across the sample cup.

99.0 (fresh sample)

A blue flash spread across the sample cup.

97.0 (fresh sample)

No flash.

97.0 (fresh sample)

No flash.

Atmospheric pressure = 100.4  kPa

Corrected flash point = 99.21 ºC

Conclusions:
The flash point of the test item, IFF 215 (Floriane), has been determined to be 99 ± 2 °C.
Executive summary:

The flash point of the test substance, IFF 215 (Floriane), was assessed according to EU Method A9 using a closed cup equilibrium method. The flash point was determined to be 99 ± 2 °C.

Description of key information

The flash point of the test substance, IFF 215 (Floriane), was assessed according to EU Method A9 using a closed cup equilibrium method. The flash point was determined to be 99 ± 2 °C. 

Key value for chemical safety assessment

Flash point at 101 325 Pa:
99 °C

Additional information