Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according EU/OECD guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method C.4-D (Determination of the "Ready" Biodegradability - Manometric Respirometry Test)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
sewage, predominantly domestic, non-adapted
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
100 mg/L
Reference substance
Reference substance:
benzoic acid, sodium salt

Results and discussion

% Degradationopen allclose all
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
8 d
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
14 d
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
22 d
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
28 d

BOD5 / COD results

Results with reference substance:
The reference compound has reached the level for ready biodegradability by 14 days.

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
under test conditions no biodegradation observed
Executive summary:

Within 28 days, a degradation of 0 % was determined for the test substance.

 

The test substance is considered to be "Not Readily Biodegradable".