Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according EU/OECD guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
84 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion