Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 september 2011 - 12 June 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. certificate)
Key result
Auto-ignition temperature:
> 400 °C
Atm. press.:
1 014 mBar
Remarks on result:
other:
Conclusions:
TCD was determined not to ignite below 400 °C.

Description of key information

TCD was found not to ignite below 400 °C.

Key value for chemical safety assessment

Additional information

An autoflammability determination was conducted as part of a package of physico-chemical testing for TCD (Huntingdon Life Sciences, 2013, Study number VHJ0054). The testing was conducted in compliance with GLP, and the autoflammability determination was performed according to EC test method A.15.

TCD was found not to ignite below 400 deg C.