Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 1, 2014 - November 28, 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-compliant study in accordance with EC A.2 , OECD 103 and EPA OPPTS 830.7220.
Cross-reference
Reason / purpose for cross-reference:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
(2008)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Version / remarks:
(1995)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7220 (Boiling Point / Boiling Range)
Version / remarks:
(1996)
Deviations:
no
GLP compliance:
yes
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Details on test material:
See endpoint 4.2.

Results and discussion

Boiling point
Remarks on result:
other: Boiling of the test substance was not observed < 400°C (673K)

Applicant's summary and conclusion

Conclusions:
In a GLP-compliant study in accordance with EC A.2, OECD 103 and EPA OPPTS 830.7220 using differential scanning calorimetry, no boiling up to 400°C was observed for the substance. It was therefore concluded that the substance has no boiling temperature.