Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-03-16 to 2016-04-05
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point:
254 °C
Atm. press.:
101.3 kPa

The flash point was corrected for the atmospheric pressure using: Corrected flash point = C + 0.23 (101.325 - p) where: C = observed flash point [°C] p = ambient atmospheric pressure [kPa].

Conclusions:
The flash point of the substance has been determined to be 254 ± 2 °C.
Executive summary:

The determination was carried out using a closed cup flash point tester using a procedure compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008. The flash point of the substance has been determined to be 254 ± 2 °C.

Description of key information

The flash point of the substance has been determined to be 254 ± 2 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
254 °C

Additional information