Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The test was conducted in accordance with ISO standard method with acceptable restrictions.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ISO 13320-1 Partikelgrößenanalyse - Laserbeugungsmethoden
Deviations:
not specified
GLP compliance:
no
Type of distribution:
counted distribution

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
23.95 µm
Remarks on result:
other: no further data
Percentile:
D50
Mean:
48.65 µm
Remarks on result:
other: no further data
Percentile:
D90
Mean:
87.13 µm
Remarks on result:
other: no further data

Applicant's summary and conclusion