First-aid measures

General advice : Move out of dangerous area.
Show the safety data sheet to the doctor in attendance.
Do not leave the victim unattended.

If inhaled : If unconscious place in recovery position and seek medical advice.
If symptoms persist, call a physician.

In case of skin contact : If on skin, rinse well with water.
If on clothes, remove clothes.

In case of eye contact : Flush eyes with water as a precaution.
Remove contact lenses.
Protect unharmed eye.
Keep eye wide open while rinsing.
If eye irritation persists, consult a specialist.

If swallowed : Keep respiratory tract clear.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.
If symptoms persist, call a physician.

Fire-fighting measures

Extinguishing media
Suitable extinguishing media :
Dry chemical
Alcohol-resistant foam
Water spray
Carbon dioxide (CO2)

Unsuitable extinguishing media: no data available

Special hazards arising from the substance or mixture
Specific hazards during firefighting: Do not allow run-off from fire fighting to enter drains or water course.

Advice for firefighters
Special protective equipment for firefighters: Wear self contained breathing apparatus for fire fighting if necessary.

Further information : Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
For safety reasons in case of fire, cans should be stored separately in closed containments.
Use a water spray to cool fully closed containers.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Personal precautions : Remove all sources of ignition.
Evacuate personnel to safe areas.
Beware of vapours accumulating to form explosive
concentrations. Vapours can accumulate in low areas.

Environmental precautions
Environmental precautions : Prevent product from entering drains.
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform
respective authorities.

Methods and materials for containment and cleaning up
Methods for cleaning up : Contain spillage, and then collect with non-combustible
absorbent material, (e.g. sand, earth, diatomaceous earth,
vermiculite) and place in container for disposal according to
local / national regulations.

Handling and storage

Precautions for safe handling
Advice on safe handling : Avoid formation of aerosol.
For personal protection see below.
Smoking, eating and drinking should be prohibited in the application area.
Take precautionary measures against static discharges.
Provide sufficient air exchange and/or exhaust in work rooms.
Open drum carefully as content may be under pressure.
Dispose of rinse water in accordance with local and national
regulations.

Advice on protection against fire and explosion: Do not spray on a naked flame or any incandescent material.
Keep away from open flames, hot surfaces and sources of ignition.
Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours).
Temperature class : no data available
Fire-fighting class : no data available
Dust explosion class : no data available

Conditions for safe storage, including any incompatibilities
Requirements for storage areas and containers: No smoking.
Keep container tightly closed in a dry and well-ventilated place.
Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Observe label precautions.
Electrical installations / working materials must comply with the technological safety standards.

Further information on storage conditions: no data available
Advice on common storage : no data available
German storage class : no data available
Other data : No decomposition if stored and applied as directed.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters
Contains no substances with occupational exposure limit values.

Exposure controls
Personal protective equipment
Hand protection : The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Eye protection : Eye wash bottle with pure water
Tightly fitting safety goggles
Skin and body protection : impervious clothing
Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Hygiene measures : Wash hands before breaks and at the end of workday.

Environmental exposure controls
General advice : Prevent product from entering drains.
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform respective authorities.

Stability and reactivity

Reactivity
none

Chemical stability
The product is chemically stable.

Possibility of hazardous reactions
Hazardous reactions : No decomposition if stored and applied as directed.Vapours may form explosive mixture with air.

Conditions to avoid
Conditions to avoid : Heat, flames and sparks.

Incompatible materials
Materials to avoid : no data available

Hazardous decomposition products
Hazardous decomposition
products: no data available
Thermal decomposition : no data available

Disposal considerations

Waste treatment methods
Product : Do not dispose of waste into sewer.
Do not contaminate ponds, waterways or ditches with chemical or used container.
Send to a licensed waste management company.
Contaminated packaging : Empty remaining contents.
Dispose of as unused product.
Do not re-use empty containers.
Do not burn, or use a cutting torch on, the empty drum.
Dispose of in accordance with local regulations.