Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

- Auto-flammability (solids): Three replicate tests performed, no ignition was observed up to 400°C, EU Method A.16, Sárvári (2015)

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
400 °C

Additional information

The study to determine the auto-flammability (solids) of the test material was conducted under GLP conditions and in accordance with the standardised guideline EU Method A.16. The study was assigned a reliability score of 1 in line with the criteria of Klimisch et al (1997).

No relative self-ignition temperature was observed up to 400 °C.