Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 807-040-5 | CAS number: 4538-42-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Hydrolysis
Administrative data
Link to relevant study record(s)
- Endpoint:
- hydrolysis
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 111 (Hydrolysis as a Function of pH)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.7 (Degradation: Abiotic Degradation: Hydrolysis as a Function of pH)
- Deviations:
- no
- Principles of method if other than guideline:
- As the substance was expected to undergo fast hydrolysis in aqueous media the hydrolysis behaviour of the test item was investigated at 20 °C and 10 °C for pH 4, pH 7 and pH 9 up to a degradation of > 90%. As hydrolysis occurred very rapidly especially at 20°C, only 3 samplings were possible (e.g at 0, 4 and 9 minutes).
- GLP compliance:
- yes (incl. QA statement)
- Radiolabelling:
- no
- Analytical monitoring:
- yes
- Details on sampling:
- - pH of the blank buffer solution: checked at the beginning of the test; the pH of the hydrolysis solution was measured at each test point
- Suitability of the HPLC system: verified on every day of application
- Recovery and the repeatability of the analytical method: checked on every day of application - Buffers:
- - Buffer pH 4: Citric acid/NaOH/NaCl (Fluka, Order no.: 33643)
- Buffer pH 7: KH2PO4/Na2HPO4 (Fluka, Order no.: 33646)
- Buffer pH 9: Na2B4O7/HCl (Fluka, order no.: 33648) - Details on test conditions:
- TEST DESIGN (pH 4, 7 and 9):
I. Preparation of the hydrolysis test solutions:
- between 45.0 and 47.0 mg of the test item were accurately weighed and dissolved to 10 mL with acetonitrile (stock solution)
- 10 mL of the tempered buffer solution was first filled into a 20 mL brown glass vial
- 100 µL of the stock solution was added into the tempered buffer solution
- To determine the starting value (T0) 200 µL of the hydrolysis test solution was immediately transferred into a sample vial and diluted with 800 µL acetone; 1 µL of this sample solution was directly injected in the gas chromatographic system
- The hydrolysis test solution in buffer was closed and incubated under nitrogen as flushing gas at 10 °C (20 °C) in a heat regulator under dark
- Due to the fast hydrolysis of the test item individual vials for the next test points had to be prepared time-shifted
- For the next test point (5 min hydrolysis time) the sample preparation procedure was repeated: 10 mL of the tempered buffer solution was filled into a 20 mL brown glass vial and 100 µL of the stock solution was added into the tempered buffer solution
- After exactly 5 min hydrolysis time 200 µL of the hydrolysis solution was diluted with 800 µL acetone and analyzed directly by GC
- The test solutions for further test points (10 min, 15 min etc.) were prepared in the same way
II. Calculation of hydrolysis:
- Hydrolysis had been observed and calculated using the total peak area values of the test item corresponding to the concentrations of the respective main component PDI in the test solutions
III. pH determination:
- The determination was done with a pH-meter equipped with a calibrated single-rod glass electrode
IV. Solubility and test concentration:
- The test item was applied as aqueous buffer solutions (including 1 % acetonitrile) with a concentration of approx. 50 mg/L
- Clear solutions were obtained - Duration:
- 30 min
- pH:
- 4
- Temp.:
- 10
- Initial conc. measured:
- 392.76 other: Peak area
- Duration:
- 10 min
- pH:
- 4
- Temp.:
- 20
- Initial conc. measured:
- 323.23 other: Peak area
- Duration:
- 40 min
- pH:
- 7
- Temp.:
- 10
- Initial conc. measured:
- 324.04 other: Peak area
- Duration:
- 10 min
- pH:
- 7
- Temp.:
- 20
- Initial conc. measured:
- 421.78 other: Peak area
- Duration:
- 20 min
- pH:
- 9
- Temp.:
- 10
- Initial conc. measured:
- 167.05 other: Peak area
- Duration:
- 10 min
- pH:
- 9
- Temp.:
- 20
- Initial conc. measured:
- 169.59 other: Peak area
- Transformation products:
- not measured
- Details on hydrolysis and appearance of transformation product(s):
- Due to the poor water solubility of the test item, a test concentration of approx. 50 mg/L (including 1 % acetonitrile as organic solvent additive) had to be applied for adequate dissolution. The low PDI concentration in the hydrolysis test solutions did not allow the identification of hydrolysis products with the applied analytical method which has to be used to follow the degradation of the parent substance. Polymeric or oligomeric ureas as potential hydrolysis products of PDI could not be determined as they are assumed to be insoluble in water.
- % Recovery:
- > 90
- pH:
- 4
- Temp.:
- 10 °C
- Duration:
- 20 min
- % Recovery:
- > 90
- pH:
- 4
- Temp.:
- 20 °C
- Duration:
- 10 min
- % Recovery:
- > 90
- pH:
- 7
- Temp.:
- 10 °C
- Duration:
- 30 min
- % Recovery:
- > 90
- pH:
- 7
- Temp.:
- 20 °C
- Duration:
- 10 min
- % Recovery:
- > 90
- pH:
- 9
- Temp.:
- 10 °C
- Duration:
- 20 min
- % Recovery:
- > 90
- pH:
- 9
- Temp.:
- 20 °C
- Duration:
- 10 min
- pH:
- 4
- Temp.:
- 20 °C
- DT50:
- < 5 min
- Type:
- (pseudo-)first order (= half-life)
- Remarks on result:
- other: estimated
- pH:
- 4
- Temp.:
- 10 °C
- DT50:
- < 5 min
- Type:
- (pseudo-)first order (= half-life)
- Remarks on result:
- other: estimated
- pH:
- 7
- Temp.:
- 20 °C
- DT50:
- < 5 min
- Type:
- (pseudo-)first order (= half-life)
- Remarks on result:
- other: estimated
- pH:
- 7
- Temp.:
- 10 °C
- DT50:
- < 5 min
- Type:
- (pseudo-)first order (= half-life)
- Remarks on result:
- other: estimated
- pH:
- 9
- Temp.:
- 20 °C
- DT50:
- < 5 min
- Type:
- (pseudo-)first order (= half-life)
- Remarks on result:
- other: estimated
- pH:
- 9
- Temp.:
- 10 °C
- DT50:
- < 5 min
- Type:
- (pseudo-)first order (= half-life)
- Remarks on result:
- other: estimated
- Details on results:
- Due to the observed rapid degradation of the test item within minutes, an exact determination of half-life time or hydrolysis rate was not possible. Therefore the halt-life times of PDI are estimated values based on the recoveries after 5 min hydrolysis time related to the initial value at 0 min, which was set to 100 %.
- Validity criteria fulfilled:
- yes
- Conclusions:
- At pH 4, 7 and 9 the substance hydrolysed immediately in water at 20 °C. The estimated half-life time was lower than 5 minutes.
- Executive summary:
The tests were performed based on OECD Guidelines for Testing of Chemicals, Section 1 – Physical-Chemical Properties, OECD 111, Council Regulation (EC) No 440/2008, Guideline Part C – Methods for the Determination of Ecotoxicity, C.7. “Abiotic Degradation: Hydrolysis as a Function of pH”. As the substance was expected to undergo fast hydrolysis in aqueous media the hydrolysis behaviour of the test item was investigated at 20 °C and 10 °C for pH 4, pH 7 and pH 9 up to a degradation of > 90%. Due to the observed rapid degradation of the test item within minutes, an exact determination of half-life time or hydrolysis rate was not possible. Therefore the halt-life times of PDI are estimated values based on the recoveries after 5 min hydrolysis time related to the initial value at 0 min, which was set to 100 %. Due to the poor water solubility of the test item, a test concentration of approx. 50 mg/L (including 1 % acetonitrile as organic solvent additive) had to be applied for adequate dissolution. The low PDI concentration in the hydrolysis test solutions did not allow the identification of hydrolysis products with the applied analytical method which has to be used to follow the degradation of the parent substance. Polymeric or oligomeric ureas as potential hydrolysis products of PDI could not be determined as they are assumed to be insoluble in water. The stability was monitored by GC analysis with FID-detection.
Reference
Solubility and test concentration:
- Based on a pre-test the test item was found to be soluble in aqueous buffer solutions (including 1 % acetonitrile) at a concentration of approx. 100 mg/L and clear solutions were obtained
- The test item was found to be soluble in this concentration which fulfills the requirements of OECD 111 and no further solubility test with organic solvent additives > 1% v/v was performed
Sterility test:
- Due to the rapid hydrolysis of up to > 90 % degradation within less than 30 minutes, biotic degradation could be excluded
- Therefore a sterility test at the end of the hydrolysis tests was not necessary and not conducted
Sensitivity:
Regarding exemplary chromatograms of the hydrolysis test solutions, the analytical method is sufficiently sensitive to quantify test item concentrations down to 10% or less of the initial concentration used in the hydrolysis experiment
Description of key information
At pH 4, 7 and 9 the substance hydrolysed immediately in water at 20 °C. The estimated half-life time was lower than 5 minutes (Neuland, 2016).
Key value for chemical safety assessment
- Half-life for hydrolysis:
- 5 min
- at the temperature of:
- 20 °C
Additional information
"Should read: < 5 min"
At 10 °C and 20 °C a recovery of the test item about or less than 50 % after 5 min hydrolysis time was obtained at pH 4, 7 and 9.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.