Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with generally accepted scientific standards and described in sufficient detail; however, non-GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Laser diffraction
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Sodium 3-[[(dimethylamino)thioxomethyl]thio]propanesulphonate
EC Number:
242-644-7
EC Name:
Sodium 3-[[(dimethylamino)thioxomethyl]thio]propanesulphonate
Cas Number:
18880-36-9
Molecular formula:
C6H13NO3S3.Na
IUPAC Name:
sodium 3-[(dimethylcarbamothioyl)sulfanyl]propane-1-sulfonate
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
1.55 µm
Remarks on result:
other: standard deviation not available
Key result
Percentile:
other: D25
Mean:
5 µm
Remarks on result:
other: standard deviation not available
Key result
Percentile:
D50
Mean:
31.15 µm
Remarks on result:
other: standard deviation not available
Key result
Percentile:
D90
Mean:
168.49 µm
Remarks on result:
other: standard deviation not available

Any other information on results incl. tables

Concentration: 0.0004 %Vol

Uniformity: 1.7

Span: 5.360

Specific surface area: 1.42 m2/g

Surface weighted mean D [3,2]: 4.220 µm

Vol. weighted mean D [4,3]: 61.233 μm

D(0.10): 1.55 μm

D(0.50): 31.15 μm

D(0.90): 168.49 μm

Applicant's summary and conclusion

Conclusions:
Average size of particles = 61.233 μm
D10 = 1.55 μm
D25 = 5.00 µm
D50 = 31.15 μm
D90 = 168.49 μm
Executive summary:

The particle size distribution of the test substance was investigated by laser diffraction based on Mie Scattering (non-GLP, 2016) and the average size of particles has been determined to be 61.233 µm (D10 = 1.55 µm, D25 = 5.00 µm, D50 = 31.15 µm, D90 = 168.49 µm).

According to the results, the inhalation of particles has to be regarded:

- ~ 75% are <100 µm (inhalable fraction)

- ~ 34% are <10 µm (thoracic fraction)

- ~20% are < 4µm (respirable fraction)