Registration Dossier

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
GLP compliance:
yes

Results and discussion

In vitro

Results
Remarks on result:
positive indication of irritation

Applicant's summary and conclusion

Interpretation of results:
Category 2 (irritating to eyes) based on GHS criteria