Administrative data

First-aid measures

Description of first aid measures

· General information: No special measures required.

· After inhalation: Supply fresh air; consult doctor in case of complaints.

· After skin contact: Generally the product does not irritate the skin.

· After eye contact: Rinse opened eye for several minutes under running water.

· After swallowing: If symptoms persist consult doctor.

· Information for doctor:

· Most important symptoms and effects, both acute and delayed No further relevant information available.

· Indication of any immediate medical attention and special treatment needed

No further relevant information available.

Fire-fighting measures

· Extinguishing media

· Suitable extinguishing agents: CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

· Special hazards arising from the substance or mixture No further relevant information available.

· Advice for firefighters

· Protective equipment: No special measures required.

Accidental release measures

· Personal precautions, protective equipment and emergency procedures:

    Wear protective clothing.

    Keep people at a distance and stay on the windward side.

· Environmental precautions:

    Do not allow to enter sewers/ surface or ground water.

· Methods and material for containment and cleaning up:

    Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

No dangerous substances are released.

Handling and storage

· Handling:

· Precautions for safe handling

     Keep away from heat and direct sunlight.

     No special measures required.

· Information about fire - and explosion protection: No special measures required.

· Conditions for safe storage, including any incompatibilities

· Storage:

· Requirements to be met by storerooms and receptacles:

    Suitable material for receptacles and pipes: steel or stainless steel.

    Store only in the original receptacle.

· Information about storage in one common storage facility: Not required.

· Further information about storage conditions: Store receptacle in a well ventilated area.

· Specific end use(s) No further relevant information available.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transportation: Not classified under the Dangerous Goods Transportation Regulations.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

· Control parameters

· Ingredients with limit values that require monitoring at the workplace: Not required.

· Additional information: The lists valid during the making were used as basis.

· Exposure controls

· Personal protective equipment:

· General protective and hygienic measures:

     The usual precautionary measures are to be adhered to when handling chemicals.

· Respiratory protection: Not required.

· Protection of hands:

     The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.

     Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/the chemical mixture.

     Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation

· Material of gloves

     The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.

· Penetration time of glove material

     The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

· Eye protection: Goggles recommended during refilling

· Body protection: Protective work clothing

Stability and reactivity

· Reactivity

· Chemical stability

· Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.

· Possibility of hazardous reactions No dangerous reactions known.

· Conditions to avoid No further relevant information available.

· Incompatible materials: No further relevant information available.

· Hazardous decomposition products: No dangerous decomposition products known.

Disposal considerations

· Waste treatment methods

· Recommendation Smaller quantities can be disposed of with household waste.

· Uncleaned packaging:

· Recommendation: Disposal must be made according to official regulations.