Immediately remove contaminated clothing.

If inhaled:
If difficulties occur after vapour/aerosol has been inhaled, remove to fresh air and seek medical attention.

On skin contact:
Wash thoroughly with soap and water.

On contact with eyes:
Immediately wash affected eyes for at least 15 minutes under running water with eyelids held open, consult an eye specialist.

On ingestion:
Rinse mouth immediately and then drink plenty of water, seek medical attention.


Most important symptoms and effects, both acute and delayed
Symptoms: The most important known symptoms and effects are described in the labelling (see section 2) and/or in section 11., Further important symptoms and effects are so far not known.


Indication of any immediate medical attention and special treatment needed
Treatment: Treat according to symptoms (decontamination, vital functions), no known specific antidote.

Fire-fighting measures

Extinguishing media
Suitable extinguishing media:
dry powder, foam

Special hazards arising from the substance or mixture
harmful vapours
Evolution of fumes/fog. The substances/groups of substances mentioned can be released in case of fire.

Advice for fire-fighters
Special protective equipment:
Wear a self-contained breathing apparatus.

Further information:
The degree of risk is governed by the burning substance and the fire conditions. Contaminated extinguishing water must be disposed of in accordance with official regulations.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Use personal protective clothing. Breathing protection required.

Environmental precautions
Contain contaminated water/firefighting water. Do not discharge into drains/surface waters/groundwater.

Methods and material for containment and cleaning up
For large amounts: Pump off product.
For residues: Pick up with suitable absorbent material. Dispose of absorbed material in accordance with regulations.

Reference to other sections
Information regarding exposure controls/personal protection and disposal considerations can be found in section 8 and 13.

Handling and storage

Precautions for safe handling
Ensure thorough ventilation of stores and work areas.

Protection against fire and explosion:
Sources of ignition should be kept well clear. Take precautionary measures against static discharges. If delivered in plastic packing, highest permissable emptying temperature is 5 Kelvin below the flash point.

Conditions for safe storage, including any incompatibilities
Further information on storage conditions: Keep container tightly closed and in a cool place.

Specific end use(s)
For the relevant identified use(s) listed in Section 1 the advice mentioned in this section 7 is to be observed.

Transport information

Land transport (ADR/RID)

UN number:
1993
Shippingopen allclose all
Class:
3
Classification code:
Flammable liquid, N.O.S. (contains Tetra-Dimethylaminoethyl titanate
Packaging group:
III
Labels:
3
SpecialProvisionsopen allclose all

Inland waterway transport (ADN(R))

UN number:
1993
Proper shipping name and description:
Flammable liquid, N.O.S. (contains Tetra-Dimethylaminoethyl titanate)
Chemical name:
Tetra-Dimethylaminoethyl titanate
Language:
English
Class:
3
Packaging group:
III
Labels:
3
Remarksopen allclose all

Marine transport (IMDG)

UN number:
1993
Proper shipping name and description:
Flammable liquid, N.O.S. (contains Tetra-Dimethylaminoethyl titanate)
Chemical name:
Tetra-Dimethylaminoethyl titanate
Class:
3
Packaging group:
III
Labels:
3
Remarksopen allclose all

Air transport ICAO/IATA

UN number:
1993
Proper shipping name and description:
Flammable liquid, N.O.S. (contains Tetra-Dimethylaminoethyl titanate)
Chemical name:
Tetra-Dimethylaminoethyl titanate
Class:
3
Packaging group:
III
Labels:
3
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure Controls/Personal Protection
Control parameters

Components with workplace control parameters


52406-71-0: Titanium(4+) 2-(dimethylamino)ethanolate
67-63-0: propan-2-ol

Exposure controls
Personal protective equipment
Respiratory protection:
Suitable respiratory protection for higher concentrations or long-term effect: Gas filter for gases/vapours of organic compounds (boiling point >65 °C, e. g. EN 14387 Type A)

Hand protection:
Chemical resistant protective gloves (EN 374)
Suitable materials short-term contact and/or splashes (recommended: At least protective index 2, corresponding > 30 minutes of permeation time according to EN 374)
butyl rubber (butyl) - 0.7 mm coating thickness
nitrile rubber (NBR) - 0.4 mm coating thickness
Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing.
Manufacturer's directions for use should be observed because of great diversity of types.

Eye protection:
Safety glasses with side-shields (frame goggles) (e.g. EN 166)

Body protection:
Body protection must be chosen depending on activity and possible exposure, e.g. apron, protecting boots, chemical-protection suit (according to EN 14605 in case of splashes or EN ISO 13982 in case of dust).

General safety and hygiene measures
Handle in accordance with good industrial hygiene and safety practice. Wearing of closed work clothing is required additionally to the stated personal protection equipment.

Stability and reactivity

Reactivity
No hazardous reactions if stored and handled as prescribed/indicated.


Chemical stability
The product is stable if stored and handled as prescribed/indicated.

Peroxides: 0 %
The product does not contain peroxides.

Possibility of hazardous reactions
No hazardous reactions known.
Stable under normal conditions.

Conditions to avoid
Avoid electro-static discharge.

Incompatible materials

Substances to avoid:
reactive chemicals, strong oxidizing agents, strong bases, strong acids

Hazardous decomposition products

Hazardous decomposition products:
carbon oxides

Disposal considerations

Waste treatment methods

Must be disposed of or incinerated in accordance with local regulations.


Contaminated packaging:
Uncontaminated packaging can be re-used.
Packs that cannot be cleaned should be disposed of in the same manner as the contents.