Registration Dossier

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Eye Contact:
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Obtain
medical attention.
Skin Contact:
Wash off immediately with plenty of water for at least 15 minutes. Get medical attention
immediately if symptoms occur.
Ingestion:
Do not induce vomiting. Call a physician or Poison Control Center immediately.
Inhalation:
Move to fresh air. If breathing is difficult, give oxygen. Do not use mouth-to-mouth resuscitation if victim ingested or inhaled the substance; induce artificial respiration with a respiratory medical device. Get medical attention immediately if symptoms occur.

Fire-fighting measures

Extinguishing media
Suitable Extinguishing Media:
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Extinguishing media which must not be used for safety reasons:
No information available.
Special hazards arising from the substance or mixture:
Thermal decomposition can lead to release of irritating gases and vapors
Advice for fire-fighters:
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective
gear. Thermal decomposition can lead to release of irritating gases and vapors.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Ensure adequate ventilation. Use personal protective equipment. Avoid dust formation.
Environmental precautions:
Should not be released into the environment.
Methods and material for containment and cleaning up:
Sweep up or vacuum up spillage and collect in suitable container for disposal. Avoid dust formation.

Handling and storage

Precautions for Safe Handling:
Wear personal protective equipment. Ensure adequate ventilation. Avoid contact with skin, eyes and clothing. Avoid dust formation. Do
not breathe dust. Use only under a chemical fume hood.
Conditions for safe storage, including any incompatibilities:
Keep containers tightly closed in a dry, cool and well-ventilated place.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not dangerous goods
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not dangerous goods
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not dangerous goods
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not dangerous goods
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters:
Components with workplace control parameters
Exposure controls:
Appropriate engineering controls:
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Personal protective equipment:
Eye/face protection:
Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection:
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and
the standard EN 374 derived from it.
Full contact
Material: Nitrile rubber
Minimum layer thickness: 0,11 mm
Break through time: 480 min
Material tested:Dermatril® (KCL 740 / Aldrich Z677272, Size M)
Splash contact
Material: Nitrile rubber
Minimum layer thickness: 0,11 mm
Break through time: 480 min
Material tested:Dermatril® (KCL 740 / Aldrich Z677272, Size M)
data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de,
test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374,
contact the supplier of the CE approved gloves. This recommendation is advisory only and must
be evaluated by an industrial hygienist and safety officer familiar with the specific situation of
anticipated use by our customers. It should not be construed as offering an approval for any
specific use scenario.
Body Protection:
impervious clothing, The type of protective equipment must be selected according to the
concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection:
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle
respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering
controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use
respirators and components tested and approved under appropriate government standards such
as NIOSH (US) or CEN (EU).
Control of environmental exposure:
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

Stability and reactivity

Reactivity:
no data available
Chemical stability:
Stable under recommended storage conditions.
Possibility of hazardous reactions:
no data available
Conditions to avoid:
Avoid moisture.
Incompatible materials:
Strong oxidizing agents, Strong acids, Strong bases, Strong reducing agents
Hazardous decomposition products:
Other decomposition products - no data available

Disposal considerations

Waste treatment methods:
Product:
Offer surplus and non-recyclable solutions to a licensed disposal company. Dissolve or mix the material
with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Contaminated packaging:
Dispose of as unused product.