Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Specific details on test material used for the study:
Batch: SC00013340
Aspect: Yellow liquid
Purity: 82.7%
Expiration date: 20 October 2015
Key result
Flash point:
84.9 °C
Atm. press.:
101.3 kPa
Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
The measured flash point of the test item is 84.9 °C.
Executive summary:

In the course of this study an important physico-chemical property, the flash point of test item was determined. The flash point provides a simple, convenient index for assessing the flammability of a wide variety of materials.

The test was performed by the help of MINIFLASH automatic flash point tester with the continuously closed cup – electric arc method according to ASTM D 6450.

The flash point of the test item is 84.9 °C.

Description of key information

The measured flash point of the test item is 84.9 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
84.9 °C

Additional information