Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 February 2015 - 28 May 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study is considered to be a reliability 1 as it has been conducted according to EU Method A.9 (Flash-Point) using the ASTM D93 closed cup method and in compliance with GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report Date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
(2008)
Deviations:
no
Qualifier:
according to
Guideline:
other: ASTM D93 (2002)
Deviations:
no
Qualifier:
according to
Guideline:
other: UN ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, Part III Section 32.4 Test methods for determining flash point and viscosity/32.4.1 Test method for non-viscous flammable liquid (2009).
Deviations:
no
GLP compliance:
yes
Type of method:
non-equilibrium method closed cup
Remarks:
ASTM D93 (Pensky-Martens)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid
Details on test material:
- Name of test material in report: IFF 09-0035
- Physical state: Clear liquid
- Storage condition of test material: At room temperature protected from light

Results and discussion

Flash point
Flash point:
87 °C
Atm. press.:
1 013 hPa

Any other information on results incl. tables

Preliminary test:

The estimated flash-point of the test substance was 86.5°C.

Main study:

Both tests showed a flash point of 87°C.

Applicant's summary and conclusion

Conclusions:
The flash point of IFF 09-0035 was determined using a reliable GLP study according to EC A.9 and ASTM D93 using the non-equilibrium closed cup method (Pensky-Martens). The flash point of the substance is 87°C at 1013 hPa.
Executive summary:

The flash point of IFF 09-0035 is 87°C according to ASTM D93 using the non-equilibrium closed cup method (Pensky-Martens).