Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 236-425-5 | CAS number: 13361-34-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP guideline study.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 1 998
- Report date:
- 1998
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 405 (Acute Eye Irritation / Corrosion)
- GLP compliance:
- yes
Test material
- Reference substance name:
- 2-ethylhexyl cyanoacetate
- EC Number:
- 236-425-5
- EC Name:
- 2-ethylhexyl cyanoacetate
- Cas Number:
- 13361-34-7
- Molecular formula:
- C11H19NO2
- IUPAC Name:
- 2-ethylhexyl 2-cyanoacetate
- Reference substance name:
- 2-ethylhexyl-cyanoacetate
- IUPAC Name:
- 2-ethylhexyl-cyanoacetate
- Details on test material:
- - Name of test substance: 2-ethylhexyl-cyanoacetate
- Chemical name: cyanoacetic acid 2-ethylhexyl ester
- Substance number: 96/219
- Batch number: ABL.NR . 13-9844
- CAS number: 13361-34-7
- Degree of purity/content: 98.5 g/100 g (GC)
- Date of manufacturing: 27-DEC-1995
- Physical state/appearance: liquid, yellowish, clear
- Stability under test conditions: The stability of the TS over the study period has been proven by reanalysis.
- Storage conditions: room temperature
Constituent 1
Constituent 2
Test animals / tissue source
- Species:
- rabbit
- Strain:
- New Zealand White
- Details on test animals or tissues and environmental conditions:
- TEST ANIMALS
- Source: Dr. K. Thomae GmbH, Biberach, FRG
- Age at study initiation: young adult animals
- Weight at study initiation: 2.48 - 2.74 kg
- Housing: single housing in stainless steel wire mesh cages with grating, floor area: 3000 cm²
- Diet: Kliba-Labordiaet 341 (Klingenthalmuehle AG, Kaiseraugst, Switzerland), about 130 g per animal per day
- Water: about 250 ml tap water per animal per day
- Acclimation period: at least 1 week
ENVIRONMENTAL CONDITIONS
- Temperature (°C): 20 - 24
- Humidity (%): 30 - 70
- Photoperiod (hrs dark / hrs light): 12 / 12
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- other: untreated eye of same animal
- Amount / concentration applied:
- TEST MATERIAL
- Amount applied: 0.1 ml
- Concentration: undiluted - Duration of treatment / exposure:
- The TS was washed out with tap water about 24 hours after application. The observation period was 72 hours
- Observation period (in vivo):
- 72 hours
- Number of animals or in vitro replicates:
- 3
- Details on study design:
- REMOVAL OF TEST SUBSTANCE
- Washing: with tap water
- Time after start of exposure: about 24 hours after application
SCORING SYSTEM: According to OECD guideline 405 (adopted Feb. 24, 1987) and EEC L 383A, B.5 (Dec. 29, 1992).
Results and discussion
In vivo
Resultsopen allclose all
- Irritation parameter:
- cornea opacity score
- Basis:
- mean
- Time point:
- other: 24, 48, 72 hours
- Score:
- 0
- Max. score:
- 0
- Reversibility:
- other: not applicable
- Irritation parameter:
- iris score
- Basis:
- mean
- Time point:
- other: 24, 48, 72 hours
- Score:
- 0
- Max. score:
- 0
- Reversibility:
- other: not applicable
- Irritation parameter:
- conjunctivae score
- Basis:
- mean
- Time point:
- other: 24, 48, 72 hours
- Score:
- 0
- Max. score:
- 0
- Reversibility:
- fully reversible within: 24 hours
- Irritation parameter:
- chemosis score
- Basis:
- mean
- Time point:
- other: 24, 48, 72 hours
- Score:
- 0
- Max. score:
- 0
- Reversibility:
- other: not applicable
- Irritant / corrosive response data:
- The average score (24 to 72 hours) for irritation was calculated to be 0.0 for corneal opacity, iris, conjunctivae redness and chemosis. The findings were reversible in all animals within 24 hours after application. Thus the study was terminated after 72 hours.
Any other information on results incl. tables
Irritant/corrosive response data for each individual animal at each observation time asa well as calculation of the means:
Animal |
Cornea |
Iris |
Conjunctivae |
||||
Opacity |
Area |
Redness |
Swelling |
Discharge |
|||
1 hour |
1 |
0 |
0 |
0 |
1 |
0 |
2 |
|
2 |
0 |
0 |
0 |
1 |
0 |
2 |
|
3 |
0 |
0 |
0 |
1 |
0 |
2 |
24 hours |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
|
2 |
0 |
0 |
0 |
0 |
0 |
0 |
|
3 |
0 |
0 |
0 |
0 |
0 |
0 |
48 hours |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
|
2 |
0 |
0 |
0 |
0 |
0 |
0 |
|
3 |
0 |
0 |
0 |
0 |
0 |
0 |
72 hours |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
|
2 |
0 |
0 |
0 |
0 |
0 |
0 |
|
3 |
0 |
0 |
0 |
0 |
0 |
0 |
Mean (24 - 72 h) |
1 |
0.0 |
|
0.0 |
0.0 |
0.0 |
|
|
2 |
0.0 |
|
0.0 |
0.0 |
0.0 |
|
|
3 |
0.0 |
|
0.0 |
0.0 |
0.0 |
|
Total mean (24 – 72 h) |
|
0.0 |
|
0.0 |
0.0 |
0.0 |
|
Applicant's summary and conclusion
- Interpretation of results:
- not irritating
- Remarks:
- Migrated information
- Conclusions:
- Under the test conditions chosen and considering the described findings the TS does not give indication of an irritant property to the eye.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.