Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was conducted in accordance with a recongised EU test guideline.
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
no
Remarks on result:
no self ignition observed under the test conditions

The test was carried out twice. A temperature-time trace is attached to show the temperature history of the sample within the temperature-programmed oven

Run 1: No exothermic activity. No self ignition.

Run 2: No exothermic activity. No self ignition.

Conclusions:
The sample does not undergo self-heating/ignition under the conditions of the test.
Executive summary:

A test was conducted in accordance with EU test method A16 to determine the auto-ignition potential of the substance. The sample was held within an open-top gauze cube of 20 mm side and 0.045 mm openings, which was placed inside a temperature-programmed oven fitted with natural air recirculation and explosion relief. The sample does not undergo self-heating/ignition under the conditions of the test.

Description of key information

The sample does not undergo self-heating/ignition under the conditions of the test.

Key value for chemical safety assessment

Additional information

A test was conducted in accordance with EU test method A16 to determine the auto-ignition potential of the substance. The sample was held within an open-top gauze cube of 20 mm side and 0.045 mm openings, which was placed inside a temperature-programmed oven fitted with natural air recirculation and explosion relief. The sample does not undergo self-heating/ignition under the conditions of the test.