Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
not specified
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid
Details on test material:
- Lot No.: SC00004526,
- Purity: 99.1 % (sum of the two isomers)
- Expiration date: August 15, 2014

Results and discussion

Flash point
Flash point:
100.5 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Conclusions:
The flash point of the test substance was determined to be 100.5 °C.