Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study not conducted to GLP, but is performed to a recognised guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method open cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: pure substance

Results and discussion

Flash pointopen allclose all
Flash point:
24 °C
Atm. press.:
1 011 hPa
Flash point:
23.5 °C
Atm. press.:
1 011 hPa

Applicant's summary and conclusion

Conclusions:
the flash point was determined to be 24°C @ 1023 hPa