Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 to 22 April 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7200 (Melting Point / Melting Range)
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 1 (2009): Freezing Point
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
< -100 °C
Atm. press.:
1 013 hPa

Results

During the cooling and the subsequent heating phase, no thermal effects were observed in the temperature range from -100 to 25 °C. It can be assumed that the test item has no melting or freezing point in this temperature range. Therefore the test item has no melting point down to a temperature of -100 °C.

Final Results

The test item has no melting point down to -100 °C at atmospheric pressure (1013 hPa) as determined by differential scanning calorimetry according to Regulation EC No. 440/2008 Method A.1. and OECD Test Guideline 102 (1995).

Conclusions:
A melting point value of <-100 °C (at 1013 hPa) was determined for the test substance according to E.U. Method A.1.

Description of key information

Melting point: <-100 °C at 1013 hPa (EU Method A.1, differential scanning calorimetry)

Key value for chemical safety assessment

Additional information