Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: MH-20/2014
Test procedure:
burning time over 250 mm for metal powders or metal alloys
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Safety Pre-Test

A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test

The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
FAT 40061/F should be considered as not highly flammable.
Executive summary:

The flamnability test was performed with FAT 40061/F according to EU method A.10 method. No ignition was observed throughout the course of the test when a 250 mm pile of test item was exposed to the flame of a teclu burner. Hence, FAT 40061/F should be considered as not highly flammable.

Description of key information

The flammability test was performed with FAT 40061/F according to EU method A.10 method. No ignition was observed throughout the course of the test when a 250 mm pile of test item was exposed to the flame of a teclu burner. Hence, FAT 40061/F should be considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification

FAT 40061/F is to be considered as not highly flammable, hence it does not warrant classification for flammability as per the Regulation (EC) No. 1272/2008.