Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: substance could not be ignited with a flame

In the preliminary test, the test item could not be ignited. Based on the results of the preliminary test, no main test was performed.

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test item could not be ignited with a flame, therefore M-DIPA is considered to be not flammable.
Executive summary:

The flammability test was performed following EC-method A.10. The test item could not be ignited with a flame in the preliminary test.

Therefore, no main test was performed. M-DIPA is considered to be not flammable.

Description of key information

The flammability test was performed following EC-method A.10. The test item could not be ignited with a flame in the preliminary test. Therefore, no main test was performed. M-DIPA is considered to be not flammable.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Source: GLP-report

Justification for classification or non-classification

Based on the data available the substance is not classified or labeled according to Directive 67/548/EEC (DSD) or Regulation 1272/2008/EC (CLP).