Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1997

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
GLP compliance:
yes
Type of method:
other: Capillary tube method using a Buchi 530 melting/boiling point apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Boiling point
Boiling pt.:
> 320 °C
Decomposition:
yes
Decomp. temp.:
137 - 154.5 °C
Remarks on result:
other: In duplicate tests, the test material did not boil below the maximum operating temperature of the equipment (approx. 320 °C). There was a possibility that the material decomposed on melting, as indicated by a colour change (Reference Section 4.2)

Applicant's summary and conclusion