Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 252-488-1 | CAS number: 35285-69-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Adsorption / desorption
Administrative data
Link to relevant study record(s)
Description of key information
Propyl 4-hydroxybenzoate (= propylparaben) (CAS 94-13-3): log Koc = 2.72 (Koc = 519.9554) at pH 7 (QSAR; Franco, Fu & Trapp 2009 for ionisable substances)
Key value for chemical safety assessment
- Koc at 20 °C:
- 519.955
Additional information
The log Pow of the substance sodium propylparaben (CAS 35285-69-9) and its corresponding acid form propyl 4-hydroxybenzoate (= propylparaben) (CAS 94-13-3) were experimentally determined to be 0.27 (at 23°C, pH 10.8) and 3.00 (at 22°C, pH 7.5). Additionally the log Pow of propyl 4-hydroxybenzoate (= propylparaben) (CAS 94-13-3) was calculated by QSAR (EPISuite) and corroborates the measured result with a log Pow value of 2.98.
In accordance with Regulation (EC) No 1907/2006, Column 2 of Annex VIII, section 9.3.1, studies on adsorption/desorption do not have to be conducted as sodium propylparaben (CAS 35285-69-9) has a low potential for adsorption based on the log Kow of < 3 and thus the endpoint is waived. However, for the purpose of the chemical safety assessment further information on the adsorption behavior was collected and is provided here using an appropriate calculation method. Sodium propylparaben (CAS 35285-69-9) is the sodium salt of the corresponding acid propyl 4-hydroxybenzoate hydroxybenzoate (= propylparaben) (CAS 94-13-3). The pKa is defined for the corresponding acid and is related to the dissociation of the hydroxylic group.
Considering the ionization properties of the substance, the adsorption potential has been calculated using Franco, Fu and Trapp‘s expressions (2009) on estimation of the organic carbon-water partitioning coefficient of ionisable organic substances. The log Kow for the neutral molecule, the pH as well as the pKa values were used as input parameters. Measured pKa values are available from the literature (see section 4.21) from which a mean pKa of 8.46 was calculated. This value was used as an input parameter for the calculation of the Koc coefficient.
The following equation was used for Koc calculation as suggested by the authors:
Koc = (10 ^ (0.54*logPn+1.11) / (1+10 ^ (pH-0.6-pKa))) + (10 ^ (0.11*logPn+1.54) / (1+10 ^ (pKa-pH+0.6)))
Where:
Pn (Kow of the neutral molecule): 2.98
pKa: 8.46
pH: 4, 7, and 9
The log Koc was calculated to be 2.72 at pH 4 and 7 and 2.5 at pH 9. These values indicate a low to moderate adsorption potential of the substance in soils and sediments. According to the Guidance on Information Requirements and Chemical Safety Assessment, Chapter R.7.1.8.5 the log D value for the ionized molecule determined around the default pH of 7 is considered more relevant for chemical safety assessment. On this basis, the calculated log Koc of 2.72 (Koc = 519.9554) at pH 7 has been used as key value for the chemical safety assessment.
Reference:
Franco A., Fu W., and Trapp S. (2009).Influence of soil pH on the sorption of ionizable chemicals: modeling advances. Environmental Toxicology and Chemistry 3: 458-464, doi: 10.1897/08-178.1
[LogKoc: 2.72]
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.