Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The vapour pressure calculation was performed according to the modified  Grain method which is proposed in Annex 1 of the EU method A.4.  (92/69/EEC). From the result  (< 1E-05 Pa) it can be concluded that no measurement is required because  the calculated value is far below the detection limit of the available  methods. Calculation result (modified Grain method): 1.91E-06 Pa

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information

The vapour pressure calculation was performed according to the modified  Grain method which is proposed in Annex 1 of the EU method A.4.  (92/69/EEC). From the result 
(< 1E-05 Pa) it can be concluded that no measurement is required because  the calculated value is far below the detection limit of the available  methods.
Calculation result (modified Grain method): 1.91E-06 Pa