Registration Dossier

Administrative data

Link to relevant study record(s)

Description of key information

No ignition was observed throughout the course of the test. 

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

A study was performed in order to determine the flammability FAT 20004

The following findings were noted:

Safety Pre-Test:

A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test:

The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

In the main test no ignition was observed throughout the course of the test. Hence, the test item FAT 20004 should be considered as not highly flammable.

Justification for classification or non-classification

No ignition was observed throughout the course of the test. Hence, the test item FAT 20004 should be considered as not highly flammable.