Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 18, 2001 till September 18, 2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study according to EU Method A.10 (Flammability (Solids)) under GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Identity: ZP-TIX 1014
Batch: NW-01-028
Purity > 99%,
Appearance: Solid
Expiration date: 30.12.2001
Storage: At room temperature at about 20°C

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

ZP-TIX 1014 could not be ignited with a flame during the preliminary test (contact time of about 2 minutes). In contact with the ignition source, ZP-TIX 1014 melted immediately and a clear, colorless melt remained. No smoke or any change in color of the ignition source was observed.

Therefore no main test was performed.

Applicant's summary and conclusion

Conclusions:
In conclusion, ZP-TIX 1014 is not "highly flammable" according to the criteria of the guideline.
Executive summary:

The determination of the flammability of the test item was performed in accordance with the EEC Directive 92/69, Part A, Methods for the determination of physico-chemical properties, A.10 "Flammability (solids)", EEC Publication No. L383, December 1992.

ZP-TIX 1014 could not be ignited with a flame during the preliminary test (contact time of about 2 minutes). In contact with the ignition source, ZP-TIX 1014 melted immediately and a clear, colorless melt remained. No smoke or any change in color of the ignition source was observed. Therefore, no main test was performed.