Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

From the three examined samples, the 10% of the sample presents a particle size lower than 0.001892 mm.

Additional information

From the experimental data obtained in the laser test of the analysed lots, it can be concluded that the 10% of the sample of dust presents a particle size lower than 0.001892 mm. In particular, from the obtained values, D10 range from 1.480 to 2.190 μm; D50 range from 6.454 to 11.007 μm; D90 range from 19.046 to 29.899 μm.

The D99 range from 37.78 to 48.68 μm.

These studies were conducted according to ISO 13320 -1 .