Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Description of key information

non oxidising

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

The determination was performed according to Regulation (EC) No 440/2008, A.17.

In the full test, the maximum burning rate of test substance mixture is lower than the maximum burning rate of the reference mixture and the ratio was calculated to be 0.35

Justification for classification or non-classification

As the experimental data provided the substance is not considered to be classified as an oxidising material.