Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Non GLP-Study but sufficiently documented.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Operating temperature
Operating temp.:
>= 30 - <= 350 °C
Sublimation:
no
Transformation products:
no

For study on stability to sunlight

Test substance stable to sunlight:
not determined

For study on stability to metals

Test substance stable to metals / metal ions:
not determined

Any other information on results incl. tables

The DSC showed no exothermal peaks. An endothermal peak was observed beginning at 139°C with a maximum of ca. 155°C, which was assigned to the melting point.