Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
bulk density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17/06/2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: No guidelines followed
Qualifier:
according to guideline
Guideline:
other: ASTM D 1895 B
Deviations:
not specified
Principles of method if other than guideline:
Bulk density was determined as the weight of material placed into 100ml calibrated cylinder divided to the cylinder volume.
GLP compliance:
no
Type of method:
other: using a calibrated cylinder
Type:
bulk density
Density:
0.97 g/cm³
Temp.:
20 °C

The weight of substance in the cylinder was 97.25 (mean of 5 replicates, RSD=2.6%). The bulk density of substance calculated from the experimental data was 0.97 g/cm3 (RSD=2.6%).

Conclusions:
The bulk density of substance calculated from the experimental data was 0.97 g/cm3 (RSD=2.6%).
Executive summary:

/

Endpoint:
bulk density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19/01/2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: no guideline followed
Reason / purpose for cross-reference:
reference to same study
Qualifier:
no guideline followed
Principles of method if other than guideline:
Bulk density was determined as the weight of material placed into 100 ml calibrated cylinder divided to the cylinder volume.
GLP compliance:
no
Type of method:
other: calibrated cylinder
Type:
bulk density
Density:
0.96 g/cm³
Remarks on result:
other: no temperature was measured

The following results were obtained: The weight of F2200 in the cylinder was 95.82 (mean of 6 replicates, RSD=1.02%).

The bulk density of F2200 calculated from the experimental data was 0.96 g/cm3 (RSD=1.02%).

Conclusions:
The bulk density of F2200 calculated from the experimental data was 0.96 g/cm3 (RSD=1.02%).

Description of key information

Bulk density of Brominated epoxy having epoxy equivalent of 400gr/eq

Key value for chemical safety assessment

Relative density at 20C:
0.97

Additional information

Bulk density of 0.97g/cm³