Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 205-769-8 | CAS number: 150-76-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: The method is similar to the EC and OECD guidelines. The test conditions are sufficiently described but the GLP are not mentioned.
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- HPLC method
- GLP compliance:
- not specified
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Type:
- log Pow
- Partition coefficient:
- 1.62
- pH:
- 2.2
- Remarks on result:
- other: no data on temperature
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- The method followed the new OECD guideline 122 (proposal) "Partition coefficient (n-Octanol/Water), pH-metric method for ionisable substances". As only few information on the test conditions and the result obtained is available (i.e. no repeated determination results), the result is considered as reliable with restrictions.
- Qualifier:
- according to guideline
- Guideline:
- other: OECD 122 pH-metric method
- GLP compliance:
- not specified
- Partition coefficient type:
- octanol-water
- Analytical method:
- other: Potentiometric analysis
- Type:
- log Pow
- Partition coefficient:
- 1.41
- Temp.:
- 23 °C
- pH:
- > 3 - < 11.5
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: Even if the method is not considered as a standard EC or OECD test guideline, the test conditions are relatively well described to assess its validity.
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- Microemulsion electrokinetic chromatography (MEEKC)
- GLP compliance:
- not specified
- Type of method:
- other: Microemulsion electrokinetic chromatography (MEEKC)
- Partition coefficient type:
- octanol-water
- Analytical method:
- other: Microemulsion electrokinetic chromatography (MEEKC)
- Type:
- log Pow
- Partition coefficient:
- 1.23
- pH:
- 7
- Remarks on result:
- other: no data on temperature
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Reliability:
- 4 (not assignable)
- Rationale for reliability incl. deficiencies:
- other: The data has been obtained according to the HPLC method but very few information is available about the test conditions (temperature, pH, mobile phase, detection). Therefore, it is not possible to assess the reliability of this study.
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- HPLC method
- GLP compliance:
- not specified
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Type:
- log Pow
- Partition coefficient:
- 1.3
- Remarks on result:
- other: no data on temperature and pH
Referenceopen allclose all
Measured Log k' (10%) = -0.41
The corresponding Log P is 1.62.
LogP = 1.41 (+/-) 0.03
Remark:
Octanol and water used in the study were not mutually presaturated.
To test the consequence of mutual solubility, the solubility data were applied for
corrections to octanol and water volumes. The authors were not sure the correction was valid
since mutual saturation proceeds slowly whereas the analysis takes no more than 10 minutes.
The corrected values for the test substance is as follows:
pKa = 10.06 +/- 0.01
logP = 1.35 +/- 0.03
Migration index obtained: MI = 4.02
Partition coefficient deduced: Log P = 1.23
The correlation was expressed by:
log P = 0.518 MI - 0.854
n = 53, r = 0.996, s = 0.094, F = 6083
where r is the correlation coefficient, s is the standard deviation from
regression, and F the value of the F-ratio between regression and residual variances.
no more data available
Description of key information
Literature values range from 1.13 to 1.62
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 1.3
- at the temperature of:
- 20 °C
Additional information
Seven data on logKo/w with reliability scores of 2 and 4 are available and give values within the narrow range from 1.13 to 1.62. These have been used in a weight of evidence approach.
Moreover, 4-methoxyphenol is one of the substances recommended as reference substances in the OECD TG 117 (HPLC method) and the draft OECD TG 122 (pH-metric method). Therefore, it can be expected that the logKow value recommended in these guidelines, which has a value of 1.34, has been peer-reviewed and considered as reliable.
Consequently, a value of 1.3 is retained for log Ko/w.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.