Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2006-12-21 to 2007-09-13
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP test
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
Cited as Directive 92/69/EEC, A.10
Deviations:
yes
Remarks:
the ignition source is a platinum wire heated by electrical power
GLP compliance:
yes (incl. QA statement)

The test item didn't burn. With the contact to the hot filament, it melts.

Interpretation of results: non flammable 

Interpretation of results:
GHS criteria not met

Description of key information

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

An A10 test has been initiated, but not completed since the product melted in contact with the flame.

Justification for classification or non-classification

Experience in handling and use of the substance provide sufficient information to indicate that it is neither flammable on contact with water nor pyrophoric.