Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study according to internationally accepted guideline but nor GLP compliant.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
no
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
gas under pressure: refrigerated liquefied gas
Details on test material:
Test item: Difluoro-bromo-benzene
CAS No.: 348-57-2
Batch No.: L39084N
Physical state: liquid
Colour: colourless
Storage: 2-8 °C, in a tightly closed container

Results and discussion

Flash point
Flash point:
66 °C
Atm. press.:
100.7 kPa
Remarks on result:
other: The measurement was carried out under environmental pressure.

Applicant's summary and conclusion

Conclusions:
The closed cup flash point of 1-bromo-2,4-difluorobenzene (CAS 348-57-2) is 66°C. According to GHS the test item is classified as flam. liquide 4. cathegory. (Accordng to CLP regulation it is not classified as flam. liquide.)