Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well-documented study report which meets basic scientific principles, but no GLP lab.
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D 56
GLP compliance:
no
Remarks:
Non GLP certified lab
Type of method:
closed cup
Flash point:
28 °C
Atm. press.:
1 atm
Conclusions:
The measured flash point was 28°C at 1 atm using test method ASTM D 56.
Executive summary:

The measured flash point was 28°C at 1 atm using test method ASTM D 56.

Description of key information

The flash point, PMcc is >23° C according to the ASTM D 56 testing methodology. 

Key value for chemical safety assessment

Additional information

The flash point, PMcc is >23° C according to the ASTM D 56 testing methodology.

Categories Display