Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 941-717-7 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Biodegradation in water: screening tests
Administrative data
- Endpoint:
- biodegradation in water: ready biodegradability
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- 11 June to 11 July 2012
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Valid an conclusive guideline study under GLP
Data source
Reference
- Reference Type:
- secondary source
- Title:
- Unnamed
- Year:
- 2 012
- Report date:
- 2012
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
- Version / remarks:
- 1992
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.4-D (Determination of the "Ready" Biodegradability - Manometric Respirometry Test)
- Version / remarks:
- Commission Regulation (EC) No. 440/2008
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- swissmedic, Bern, 11 January 2011
Test material
- Reference substance name:
- L-menthan-3-one
- EC Number:
- 237-926-1
- EC Name:
- L-menthan-3-one
- Cas Number:
- 14073-97-3
- Molecular formula:
- C10H18O
- IUPAC Name:
- 2-isopropyl-5-methylcyclohexanone, (2S,5R)-
- Details on test material:
- - Name of test material (as cited in study report): Menthone-L/ Isomenthone-D
- Substance type: Organic chemical, Isoprenoid
- Storage condition of test material: At room temperature at 20 °C ± 5 °C, in the dark
Constituent 1
Study design
- Oxygen conditions:
- aerobic
- Inoculum or test system:
- activated sludge, domestic, non-adapted
- Details on inoculum:
- - Source of inoculum/activated sludge: Sludge from a wastewater treatment plant (ARA Ergolz II, Füllinsdorf, Switzerland) was washed three times with tap water by centrifugation and the supernatant liquid phase was decanted.
- Concentration of sludge: A homogenized aliquot of the final sludge suspension was weighed, thereafter dried and the ratio of wet to dry weight was calculated. Based on this ratio, calculated amounts of wet sludge were suspended in test water to obtain a concentration equivalent to 4 g dry material per litre and stored.
- Storage conditions: During the holding period prior to use, the sludge was aerated at room temperature.
- Storage length: 2 days
- Preparation of inoculum for exposure: Prior to use, the sludge was first thoroughly mixed and then diluted with test water to a concentration of 1 g per litre (dry weight basis).
- Initial cell/biomass concentration: Based on the determined dry weight of this diluted activated sludge, defined amounts were added to test water to obtain a final concentration of 30 mg dry material per litre.
- Water filtered: No - Duration of test (contact time):
- 28 d
Initial test substance concentrationopen allclose all
- Initial conc.:
- 20 mg/L
- Based on:
- test mat.
- Initial conc.:
- >= 58 - <= 59 mg/L
- Based on:
- ThOD/L
Parameter followed for biodegradation estimation
- Parameter followed for biodegradation estimation:
- O2 consumption
- Details on study design:
- TEST CONDITIONS
- Composition of medium: The test water was prepared according to the testing guidelines. Analytical grade salts were dissolved in purified water to obtain the following stock solutions:
1) 8.50 g/L KH2PO4, 21.75 g/L K2HPO4, 33.40 g/L Na2HPO4 x 2H2O, 0.50 g/L NH4Cl; The pH of this solution was 7.4.
2) 22.50 g/L MgSO4 x 7H2O
3) 36.40 g/L CaCl2 x 2H2O
4) 0.25 g/L FeCl3 x 6H2O, stabilized with one drop of concentrated HCl per litre
To obtain the final test water, 10 mL of stock solution No. 1) and 1 mL each of stock solution nos. 2), 3) and 4) were combined and made up to 1000 mL with purified water. The pH was adjusted from 8.1 to 7.4 with a diluted hydrochloric acid solution.
- Additional substrate: None
- Solubilising agent: No emulsifiers or solvents were used.
- Test temperature: 22 °C, maintained with a built-in thermostat and checked on each working day
- pH: The pH measured in all flasks at the start of the test was found to be 7.4. At the end of exposure (day 28), pH values of 7.5–8.1 were measured.
- pH adjusted: No
- Suspended solids concentration: 30 mg dry material/L
- Continuous darkness: Yes
TEST SYSTEM
- Culturing apparatus: The test flasks (500 mL reaction vessels, labelled with the necessary information to ensure unmistakable identification) were incubated under continuous stirring in a SAPROMAT D12 (Voith GmbH, Heidenheim, Germany).
- Number of culture flasks/concentration: 2
- Method used to create aerobic conditions: Electrochemical analysis process: The biodegradation process consumes the dissolved oxygen in the test medium and generates CO2. The CO2 is adsorbed by soda lime, which results in a decrease of the total pressure in the airtight test flasks. The pressure drop is detected and converted into an electrical signal by means of an electrode type manometer. The consumed oxygen is replaced by electrolytically generated oxygen from a copper sulphate solution.
- Measuring equipment: Oxygen consumption was recorded manually by taking a daily reading at least on each working day.
- Test performed in closed vessels due to significant volatility of test substance: Yes, as required by the guideline
- Details of trap for CO2: As required by the guideline (soda lime)
SAMPLING: Not required according to the guideline as the oxygen consumption is followed by reading of the instruments displaying the quantity of electrochemically resupplied oxygen
CONTROL AND BLANK SYSTEM
- Inoculum blank: 2 replicates
- Abiotic sterile control: Not employed
- Toxicity control: 1 replicate (20 mg/L test item corresponding 59 mg ThOD/L plus 100 mg/L reference substance corresponding to 167 mg ThOD/L)
- Other: The reference item sodium benzoate was tested simultaneously under the same conditions as the test item and functioned as a procedure control. A stock solution containing 2.5 g sodium benzoate per litre test water was prepared by completely dissolving 250 mg sodium benzoate in 100 mL test water. From this stock solution, 10 mL aliquots were added to the corresponding test flasks containing test water.
Reference substance
- Reference substance:
- benzoic acid, sodium salt
- Remarks:
- 99.7 % purity, Sigma-Aldrich product no. 71295, Lot no. BCBB4145, expiration date Nov-2015, used at 100 mg/L corresponding to 167 mg ThOD/L
Results and discussion
% Degradation
- Parameter:
- % degradation (O2 consumption)
- Value:
- 52
- Sampling time:
- 28 d
- Remarks on result:
- other: Replicates 1 and 2
- Details on results:
- The percent biodegradation of the test item was calculated based on the theoretical oxygen demand (ThOD) of 2.9 mg oxygen/mg test item. The biochemical oxygen demand (BOD) of the test item in the test media significantly increased from exposure day 2 to day 13, corresponding to a mean biodegradation from 0 % to 50 %, respectively. Thereafter the biodegradation increased marginally until test termination. At the end of the 28-day exposure period, the mean biodegradation of the test item amounted to 52 % of the ThOD.
BOD5 / COD results
- Results with reference substance:
- The results are presented in Table 1 and Table 2 and in the attached Figure. The percent biodegradation of the reference item sodium benzoate was calculated based on the theoretical oxygen demand of 1.67 mg oxygen/mg (ThOD). In the procedure controls, the reference item sodium benzoate was degraded by an average of 89 % by exposure day 14, thus confirming suitability of the activated sludge. At the end of the test (day 28), the reference item was degraded by an average of 93 %.
Any other information on results incl. tables
Table 1: Oxygen Consumption in the Test Flasks
Tim [d] |
Cumulative oxygen consumption [mg/L] |
||||||
Test item |
Inoculum |
Procedure |
Toxicity |
||||
Replicate No. |
Replicate No. |
Replicate No. |
Replicate No. |
||||
1 |
2 |
1 |
2 |
1 |
2 |
1 |
|
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
1 |
3 |
2 |
4 |
14 |
16 |
17 |
2 |
3 |
4 |
2 |
5 |
91 |
93 |
96 |
3 |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
4 |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
5 |
15 |
11 |
7 |
10 |
134 |
137 |
143 |
6 |
30 |
15 |
7 |
11 |
141 |
143 |
151 |
7 |
32 |
28 |
9 |
12 |
146 |
149 |
165 |
8 |
35 |
32 |
11 |
14 |
151 |
153 |
174 |
9 |
37 |
35 |
11 |
15 |
153 |
156 |
179 |
10 |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
11 |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
12 |
44 |
42 |
13 |
16 |
161 |
164 |
188 |
13 |
47 |
44 |
13 |
20 |
163 |
167 |
191 |
14 |
47 |
45 |
15 |
20 |
164 |
168 |
191 |
15 |
47 |
46 |
15 |
20 |
165 |
170 |
191 |
16 |
48 |
47 |
15 |
20 |
166 |
172 |
192 |
17 |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
18 |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
19 |
49 |
48 |
15 |
21 |
168 |
175 |
193 |
20 |
50 |
49 |
15 |
22 |
169 |
177 |
195 |
21 |
50 |
49 |
15 |
23 |
169 |
178 |
195 |
22 |
51 |
50 |
15 |
24 |
171 |
179 |
197 |
23 |
51 |
51 |
15 |
25 |
171 |
180 |
197 |
24 |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
25 |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
26 |
51 |
51 |
15 |
26 |
171 |
180 |
199 |
27 |
52 |
52 |
15 |
28 |
172 |
181 |
201 |
28 |
52 |
52 |
15 |
28 |
172 |
181 |
201 |
-- No reading taken
Table 2: Biodegradation in the Test Flasks
Time [d] |
Percentage Biodegradation¹ |
||||
Test item |
Procedure control |
Toxicity control |
|||
Replicate No. |
Replicate No. |
Replicate No. |
|||
1 |
2 |
1 |
2 |
1 |
|
0 |
0 |
0 |
0 |
0 |
0 |
1 |
-3* |
0 |
7 |
8 |
6 |
2 |
-1* |
1 |
52 |
54 |
41 |
3 |
-- |
-- |
-- |
-- |
-- |
4 |
-- |
-- |
-- |
-- |
-- |
5 |
11 |
4 |
75 |
77 |
60 |
6 |
36 |
10 |
79 |
80 |
63 |
7 |
37 |
30 |
81 |
83 |
68 |
8 |
38 |
33 |
83 |
84 |
72 |
9 |
41 |
37 |
84 |
86 |
74 |
10 |
-- |
-- |
-- |
-- |
-- |
11 |
-- |
-- |
-- |
-- |
-- |
12 |
50 |
47 |
88 |
90 |
77 |
13 |
52 |
47 |
88 |
90 |
77 |
14 |
50 |
47 |
88 |
90 |
77 |
15 |
50 |
48 |
88 |
91 |
77 |
16 |
52 |
50 |
89 |
93 |
77 |
17 |
-- |
-- |
-- |
-- |
-- |
18 |
-- |
-- |
-- |
-- |
-- |
19 |
53 |
51 |
90 |
94 |
77 |
20 |
54 |
52 |
90 |
95 |
78 |
21 |
53 |
51 |
90 |
95 |
78 |
22 |
54 |
52 |
91 |
96 |
79 |
23 |
53 |
53 |
90 |
96 |
78 |
24 |
-- |
-- |
-- |
-- |
-- |
25 |
-- |
-- |
-- |
-- |
-- |
26 |
52 |
52 |
90 |
96 |
79 |
27 |
52 |
52 |
90 |
96 |
79 |
28 |
52 |
52 |
90 |
96 |
79 |
Mean (day 28) |
52 |
93 |
not applicable |
¹ Corrected for the mean oxygen uptake of the inoculum controls
-- Not determined
* Negative value due to higher oxygen consumption in the inoculum controls than in the test flasks with test item.
Validity of the Test
The results are considered valid since the following criteria are met:
The mean oxygen demand of the inoculated mineral medium (inoculum control) was 22 mg oxygen/L within 28 days (criterion: normally 20–30 mg oxygen/L but not greater than 60 mg oxygen/L). No difference between the degradation rates of the replicate test vessels containing the test item, test water and inoculum was observed at the end of the test (criterion: not more than 20 % deviation at the time the plateau is reached, at the end of the test or at the end of the 10-day window, as appropriate). The percentage degradation of the reference item reached 76 % on day 5 (criterion: at least 60 % of ThOD in a 10-day window by day 14). The pH of all inoculated test vessels was in the range 7.5–8.1 at the end of the exposure period of 28 days (criterion: pH inside the range 6.0–8.5 after 28 days).Applicant's summary and conclusion
- Validity criteria fulfilled:
- yes
- Interpretation of results:
- inherently biodegradable
- Conclusions:
- Based on oxygen consumption 50 % biodegradation in a 10-day and total 52 % within 28 days, substance to be considered as inherently biodegradable.
- Executive summary:
The biodegradation of the test item, consisting of the naturally occurring menthone isomers in a composition of 84.5 % L-menthan-3-one (CAS 14073-97-3) and 15.1 % D-Isomenthone (CAS 1196-31-2), was investigated in a valid, GLP-compliant study using the manometric respirometry method according to the OECD TG 301 F (1992).
The test micro-organism inoculum consisted of non-adapted activated sludge from a municipal sewage water treatment plant. The parameter followed in duplicate for biodegradation estimation was the oxygen consumption measured as oxygen consumption in the test vessels. Readings were made on every working day. The percent biodegradation of the test item in the firmly closed test vessels was calculated based on the Theoretical Oxygen Demand (ThOD) of 2.9 mg oxygen/mg test item.
During the 28 days of incubation at 22 °C the Biochemical Oxygen Demand (BOD) of the test item in the test media significantly increased from exposure day 2 to day 13, corresponding to a mean biodegradation from 0 % to 50 %, respectively. Thereafter the biodegradation increased marginally until test termination. At the end of the 28 day exposure period, the mean biodegradation of the test item amounted to 52 % of the ThOD. The 10-day window was started on day 5 or 6 and ended on day 15 or 16 in the replicates 1 and 2, respectively, when 50 % biodegradation was recorded. Consequently, the test item was found to be biodegradable under the test conditions within 28 days. However, the pass level for ready biodegradability, i.e. biodegradation of at least 60 % of the ThOD in a 10-day window within the 28 day period of the test, was not reached, the substance therefore is to be considered as inherently biodegradable.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.